Products Products
Products
FISHER™ DVI Desuperheaters

This desuperheater injects spraywater in the outlet of the venturi section, assuring excellent mixing and rapid atomization. The DVI desuperheater is installed between flanges in DN25 through DN600 (NPS 1 through 24) steam lines. There are no moving parts, and the water injection pattern provides rapid and thorough cooling. It is intended for applications with moderate load changes and low-velocity steam.

Main Features
  • Precise temperature control, close to saturation. Optimized spray pattern with optional nozzle technology allows a wide operating range for optimal mixing and fast vaporization under all operating conditions
  • The nozzles can be easily removed, maintained or replaced without having to replace the entire unit
  • The valve body is made of forged material with no welded seams
  • Can be installed at any convenient location in the pipeline
  • Can be mounted on flanged steam pipes
  • Sizes down to NPS 1
FISHER™ DVI Desuperheaters
Specifications
  • Valve Size: NPS 1 to NPS 24
  • Pressure Rating: ANSI CL150 to 1500
  • End Connection Styles: RF flanged, RTJ,Wafer
  • Maximum CV: 9.48
  • Material: SA105 carbon steel, chromium-molybdenum alloy steel (F22, F91)
  • Other Configurations: Contact us for more information
Applications
  • Power industry: auxiliary steam, HRSG interstage cooling, HP/RH thermostat spray
  • Process Control: Pressure Reducing Stations, Process Steam Relief, High Pressure to Low Pressure Relief, Vent Steam Relief, Auxiliary Steam
  • Medium load variations and low-flow steam